Distributed access, node splits and PON overlays push fiber deeper and add terminations at the headend, the hub and the edge. One Optics builds the passive pieces in between, with APC polish where reflections matter.

SC/APCSA builds, rack and wall
LC/APCLA for density
144FWall mount max
USAMade in USA enclosures
From headend to node

Our rack and wall mount enclosures can be ordered loaded for APC: SA (SC/APC) or LA (LC/APC) plates with matching pigtails, spliced on trays (or in OOFC cassettes in the HD1U, the HD3U family and HD Slim). The same HD adaptor plates fit rack and wall mount enclosures, so headend, hub and hut spares are interchangeable.

Network Diagram
CATV and PON network diagram: headend racks, wall-mount huts and cabinets, and preterminated OSP to nodesCATV and PON network diagram: headend racks, wall-mount huts and cabinets, and preterminated OSP to nodesHEADEND / HUBOSP entrance, SC/APC patch, spliceHUT / CABINETWall-mount patch and spliceOUTSIDE PLANTFeeder, closures, dropsNODES & PONDAA, RFoG, splitter cabinetsHEADEND RACKHD9U stackHD9U-R-SA-432HD6U stackHD6U-R-SA-288HD3UHD3U-[L/R]-HD1UHD1U-L-SA-24HD3US1,728F / 3USC/APC or LC/APCribbon or loose tubeFEC-691224 x 288F traysBig OSP feeds:one 6,912F ribbonOSP cable in,plenum cables outCCAP core, OLT, transportand optics (by others)SX- / DX- jumpersOSP feeder cable (by others)WMHD6XWMHD6X-L-SA-72WMHD2XWMHD2X-[L/R]-PigtailsPT-L-SA-12-3MRPD shelf, OLToptics (by others)Lockable doors forshared huts andstreet cabinets; sameHD plates as therack enclosures.ClosurePreterm OSPPTO-12 to 144FCorning ALTOScable, SMF-28Ultra fiber;ends to orderFactory-terminated:no fieldterminationat the nodeDAA nodeR-PHY / R-MACPHY (by others)RFoG / fiber-deep nodeN+0 or node split (by others)PON splitter cabinetsplitters by othersNode splits, N+0 rebuilds and new PONserving areas each add fiber at theedge. Preterminated SC/APC cablesdrop in from the nearest closure;headend and hut panels take thenew counts on the same HD plates.One Optics product (part number family)Customer equipment and optics (by others)One Optics cable (PTO- preterm, jumpers)Cable by others (feeder, OSP)
CATV and PON: headend racks on HD3U, HD6U and HD9U stacks in SC/APC, wall mounts in huts and street cabinets, and PTO- preterminated outside plant cable to DAA nodes and PON splitter cabinets.
Application Guide

Download the CATV & PON Application Guide

Free PDF, no sign-up: network diagram, product-fit table, example builds and contacts.

PDF
Download the Guide

Direct download, no email needed.

Rack patch and splice
Headend & Hub

Rack Patch and Splice

HD3U stacks carry SC/APC ribbon builds (HD6U-R-SA-288, HD9U-R-SA-432); the HD3US keeps splicing away from live jumpers and the HD1U covers small hubs.

Wall mount patch and splice
Huts & Cabinets

Wall Mount Patch and Splice

Separate lockable doors keep the splice side closed while technicians patch.

Terminated before it ships
Nodes & Drops

Terminated Before It Ships

Preterminated outside plant cable and APC pigtails and jumpers cut field splicing at the node.

Build America, Buy America (BABA) compliant, self-certified; compliance letter available on request (excludes fiber jumpers, MPO jumpers, pigtails and Cat 6 copper).

Typical Builds

  • Headend entrance: FEC-6912 (48 x 144F exit configuration, plates set for bottom entry), a bottom-entry 6,912F feed out to 48 x 144F PTP- plenum preterms. Outside runs to the nodes use PTO- OSP preterms.
  • Headend / hub patch field: HD9U-R-SA-432, 432 SC/APC ports in 9U, with DX-SASA jumpers.
  • Hut to node: WMHD6X-L-SA-72 on the wall and a PTO- preterminated cable to each new node.